Description
Deye SUN three-phase hybrid inverters (5-25kW)
Maximum. DC input power: 5000-25000
Maximum efficiency: 97.00%
MPPT Input voltage range: 150-850V
Maximum DC input voltage: 180-1000V
Protection class: IP65
Available battery type: lithium-ion
Battery voltage range: 160-700V
Can only work with 5kWh batteries
Dimensions: 408 × 638 × 2237 mm
Available battery list Deye Approved Battery list
Controls: LCD screen, touch key, app, website
Warranty: 5 years with the possibility of extension
Country of origin: China
Delivery within 7 working days
Technical Specification (in English). Download datasheet_SUN-(5-25)K-SG01HP3 hight voltage
Model | SUN-5K-SG01HP3-EU-AM2 | SUN-6K-SG01HP3-EU-AM2 | SUN-8K-SG01HP3-EU-AM2 | SUN-10K-SG01HP3-EU-AM2 | SUN-12K-SG01HP3-EU-AM2 | SUN-15K-SG01HP3-EU-AM2 | SUN-20K-SG01HP3-EU-AM2 | SUN-25K-SG01HP3-EU-AM2 | |
Battery Input Data | |||||||||
Battery Type | Lithium-ion | ||||||||
Battery Voltage Range (V) | 160~700 | ||||||||
Max. Charging Current (A) | 30 | 37 | 50 | ||||||
Max. Discharging Current (A) | 30 | 37 | 50 | ||||||
Number of Battery Input | 1 | ||||||||
Charging Strategy for Li-Ion Battery | Self-adaptation to BMS |
PV String Input Data | |||||||||
Max. DC Input Power (W) | 6500 | 7800 | 10400 | 13000 | 15600 | 19500 | 26000 | 32500 | |
Max. DC Input Voltage (V) | 1000 | ||||||||
Start-up Voltage (V) | 180 | ||||||||
MPPT Range (V) | 150-850 | ||||||||
Full Load DC Voltage Range (V) | 195-850 | 195-850 | 260-850 | 325-850 | 340-850 | 420-850 | 500-850 | 625-850 | |
Rated DC Input Voltage (V) | 600 | ||||||||
PV Input Current (A) | 20+20 | 26+20 | 26+26 | ||||||
Max. PV ISC (A) | 30+30 | 39+30 | 39+39 | ||||||
No.of MPP Trackers | 2 | ||||||||
No.of Strings per MPP Tracker | 1+1 | 2+1 | 2+2 |
AC Output Data | ||||||||
Rated AC Output and UPS Power (W) | 5000 | 6000 | 8000 | 10000 | 12000 | 15000 | 20000 | 25000 |
Max. AC Output Power (W) | 5500 | 6600 | 8800 | 11000 | 13200 | 16500 | 22000 | 27500 |
AC Output Rated Current (A) | 7.6/7.3 | 9.1/8.7 | 12.2/11.6 | 15.2/14.5 | 18.2/17.4 | 22.8/21.8 | 30.4/29 | 37.9/36.3 |
Max. AC Output Current (A) | 8.4/8 | 10/9.6 | 13.4/12.8 | 16.7/16 | 20/19.2 | 25/24 | 33.4/31.9 | 41.7/39.9 |
Max. Three-phase Unbalanced Output Current(A) | 13 | 13 | 18 | 22 | 25 | 30 | 35 | 41.7 |
Generator input/Smart load /AC couple current (A) | 7.6/40/7.6 | 9.1/40/9.1 | 12.2/40/12.2 | 15.2/40/15.2 | 18.2/80/18.2 | 22.8/80/22.8 | 30.4/80/30.4 | 37.9/80/37.9 |
Max. Continuous AC Passthrough (A) | 40 | 80 | ||||||
Peak Power (off grid) | 1.5 time of rated power, 10 S | |||||||
Output Frequency and Voltage | 50/60Hz;3L/N/PE 220/380Vac,230/400Vac | |||||||
Power Factor | 0.8 leading to 0.8 lagging | |||||||
Grid Type | Three Phase | |||||||
Total Harmonics Current Distortion (THDi) | <3% (of nominal power) | |||||||
DC current injection | <0.5% And |
Efficiency | |
Max. Efficiency | 97.60% |
Euro Efficiency | 97.00% |
MPPT Efficiency | 99.90% |
Protection | |
Integrated | Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection, Surge Protection, Arc Fault Circuit Interruption (AFCI optional) |
Output Over Voltage Protection | DC Type II / AC Type Ⅲ |
Certifications and Standards | |
Grid Regulation | IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE 217002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 |
Safety EMC / Standard | IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 |
General Data | |||
Operating Temperature Range (℃) | -40~60℃, >45℃ Derating | ||
Cooling | Free Cooling | Smart cooling | |
Noise (dB) | ≤55 dB | ||
Communication with BMS | CAN | ||
Weight (kg) | 30.5 | ||
Cabinet Size (WxHxD mm) | 408×638×237 (Excluding Connectors and Brackets) | ||
Protection Degree | IP65 | ||
Installation Style | Wall-mounted | ||
Warranty | 5 Years (10 Years Optional) |